Denso RC5 Spécifications Page 179

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 182
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 178
159
If you do not use optional cables listed on the previous page, use the recommended
connectors and cables listed below.
Recommended Connectors for I/O Cables and Cable Standards
Connector
name
Connector
model/manufacturer
Cable Standards Remarks
OUTPUT
PCR-E68FS connector
PCS-E68LA cover
Honda Communications
Industry Co., Ltd.
UL2789 - With shield
Equivalent to AWG28-68P
HAND I/O
PCR-E20FS connector
PCS-E20LA cover
Honda Communications
Industry Co., Ltd.
UL2789 - With shield
Equivalent to AWG28-20P
INPUT
PCR-E50FS connector
PCS-E50LA cover
Honda Communications
Industry Co., Ltd.
UL2789 - With shield
Equivalent to AWG28-50P
I/O
POWER
DE-9P connector
DE-C4-J6 cover
Japan Aviation
Electronics Industry, Ltd.
UL2405 - With shield
Equivalent to AWG20-2P
Caution: Be sure to modify the
shielding wire at the end of the
cable to be used, as shown
below. Without this modification,
the robot may malfunction due to
noise.
I/O cable
Braided
shielding wire
The connector shell
should be made of
conductive metal.
Crimp terminal
Vinyl tube
Shielding wire
I/O power
connector
Fasten to the connecto
r
Vinyl tube
Modifying the Shielding Wire (Example)
Vue de la page 178
1 2 ... 174 175 176 177 178 179 180 181 182

Commentaires sur ces manuels

Pas de commentaire