116
Parameter details
No. Parameters Function
1
State Output
If you do not need to confirm the Robot power ON complete
signal with the external equipment (e.g., when using the robot
controller standalone in running your robot), then you may set
this parameter to any choice other than "enable." The Robot
power ON complete port may serve as a user I/O port.
2
Run Ready
Output
You may set this parameter to any choice other than "enable" if:
- it is possible to set up all of the Motor power ON, CAL
execution, SP100, and Switch to Ext Mode functions at one
time so that you do not need to manage those signal lines
individually or
- if the system can treat the Auto mode output being OFF as a
condition required for teaching.
The External mode, CAL complete, and Teaching signal lines
may serve as user I/O signal lines.
When those signal lines serve as user I/O signal lines, the ON
conditions of the Servo ON output signal (displayed as Run
Ready) are: Servo ON + CAL complete + External mode. If one
or more of those three signal lines are turned OFF, the Servo ON
output signal goes OFF.
And when the Auto mode output signal is OFF, the system will
interpret it as in teaching.
3
Run Program
Output
If you will not run more than one programs concurrently or use
the Continue function, then you may set this parameter to any
choice other than "enable." The Program start reset,
Single-cycle complete, and Continue start permit ports may
serve as user I/O ports.
When those ports serve as user I/O ports, the system may use
the Robot running signal instead of Program start reset signal for
starting a program from the external equipment.
And the system may use the Robot running signal being OFF
instead of a Single-cycle complete signal.
Note that the above signal substitution may be allowed only
when you will not run programs concurrently.
4
Error Output
If you do not need to get error codes from the external
equipment (e.g., when using the robot controller standalone in
running your robot), then you may set this parameter to any
choice other than "enable." The error code output ports may
serve as user I/O ports.