Denso RC5 Spécifications Page 116

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 182
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 115
96
Example of program start signal fall (OFF) timing
a) The following figure shows how to make the program start signal fall
with a robot system output (program start reset output).
When the robot program starts to run, a program start reset signal is
output. The external device receives it and makes the program start
signal fall (OFF).
Robot status
Wait for start
or preceding cycle
Single-cycle operation
Program start ON
reset (output) OFF
Program start ON (shorted)
signal (input) OFF (open)
Example of Program Start Signal Fall Timing-1
b) The figure below shows how to make the program start signal fall with
the simplified method (1 shot method using a timer).
Robot status
Wait for start
Single-cycle operation
Program start ON (shorted)
signal (input) OFF (open)
50 ms. or more re
q
uired
Example of Program Start Signal Fall Timing-2
Caution Although the 1 shot method is easy, the timer setting for
falling to raise the program start signal in the middle of the
preceding cycle is difficult.
Use this method only to raise the program start signal after
the robot stops at the end of each cycle.
The status of the robot-in-operation, program start reset and
single cycle end output signals changes in sequence after
the program start signal is input (T1T2T3 in the figure
given on the next page).
The change of the status of these signals takes place within
100 msec. after the program start signal rises (ON). See the
next page.
Vue de la page 115