Denso RC5 Spécifications Page 105

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 182
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 104
85
4.2.17 Emergency Stop (Output from a contact)
(1) Function
This signal outputs from a contact exclusively designed for an emergency
stop circuitry you may configure. It allows red mushroom buttons provided
on the front panel of the robot controller, on the teach pendant, and on the
operating panel to be used as emergency stop buttons of the facilities.
A 0.3A fuse is built in the contact.
(2) Terminal number
No. 10 of connector CN10: Emergency stop (+)
No. 10 of connector CN10: Emergency stop (-)
(3) Usage
This signal is used to stop the facilities or robot in an emergency. (Refer to
Subsection 5.2.4 "Emergency Stop Circuit.")
(4) Contact
This contact is a normal close one (b contact). If any of the emergency stop
buttons is pressed, then the contact turns off to output an emergency stop
signal.
Vue de la page 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 181 182

Commentaires sur ces manuels

Pas de commentaire