Denso RC5 Spécifications Page 176

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 182
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 175
156
6.3 Wiring Notes for Robot Controller I/O Connectors (PNP
type)
After the wiring of the controller's I/O connectors is completed, check the following
before turning ON the power:
Check point (1)
Using a circuit tester, check across the "+24V terminal" and "0V terminal" of each
connector and across the "E24V terminal" and the "E0V terminal" to see that there is
no continuity. See the figure below and the table given on the next page.
Caution: If the connector wiring between the robot controller's "+24V
terminal" and "0V terminal" and between the "E24V terminal" and
the "E0V terminal" is shorted, damage to the power circuit of the
Robot Controller will result.
Check point (2)
Using a circuit tester, check across "each signal Output terminal" and "+24V terminal"
or "E24V terminal" of each connector to see that there is no continuity. See the figure
below and the table given on the next page.
Caution: If the wiring between "each signal Output terminal" and "+24V
terminal" or "E24V terminal" of each connector is shorted, damage
to the Output circuit and power circuit of the robot controller will
result.
Caution: Wind adhesive vinyl tape around all ends of the unconnected
wiring of each connector to prevent them from contacting other
wiring and parts, which results in shorting.
Robot
controller
Circuit tester
“+24V terminal” and
“E24V terminal” of the
controller
“0V terminal” and
“E0V terminal” of the
controller
External
device
Checking Example
Vue de la page 175

Commentaires sur ces manuels

Pas de commentaire