Vue de la page 668
Chapter 22 Appendices
22-17
No. Items
Factory
default
Powering-on
default
Description Comments
81 Damper setting rate
(RX)
(For 6-axis robot)
10000 10000 Damping ratio around the X-axis under
compliance control
82 Damper setting rate
(RY)
(For 6-axis robot)
10000 10000 Damping ratio around the Y-axis under
compliance control
83 Damper setting rate
(RZ)
(For 6-axis robot)
10000 10000 Damping ratio around the Z-axis under
compliance control
Can be set with
SetDampRate or
ResetDampRate.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
84
Compliance control
mode
(For 6-axis robot)
11
If lowest bit is 0: Compliance speed
control mode
If 2nd lowest bit is 1: Disables the gravity
compensation feature under compliance
control
Can be set with
SetCompVMode,
ResetCompV
Mode,
SetCompControl,
or SetCompF
Control.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
86 Antivibration setting
(For 6-axis robot)
0 Last value at
powering-off
1: Residual vibration reduction control
mode
Can be set with
SetVibControl or
ResetVibControl.
87 Compliance control
ON/OFF (For 6-axis
robot)
0 0 1: Under compliance control Can be set with
SetCompControl,
SetCompF
Control, or
ResetComp
Control.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
88
Coordinates for
compliance control
(For 6-axis robot)
00
0: Base coordinates
1: Tool coordinates
2: Work coordinates
Can be set with
SetFrcCoord.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
89
Force limit rate (+X)
(For 6-axis robot)
10000 10000
Force control rate along the +X axis
under compliance control
90 Force limit rate (+Y)
(For 6-axis robot)
10000 10000 Force control rate along the +Y axis
under compliance control
91
Force limit rate (+Z)
(For 6-axis robot)
10000 10000
Force control rate along the +Z axis
under compliance control
Can be set with
SetFrcCoord.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)