12-90
ST_ResetFrcLimit (Statement) [Ver.1.9 or later]
Function
Initializes the force limiting rates (exclusively designed for 6-axis robots).
Format
ST_ResetFrcLimit
Explanation
Initializes the force limiting rates. All rates along and about X, Y, and Z axes are set to
100%.
Related Terms
ST_SetFrcLimit
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm semaphore obtained, Error
"21F7 Cannot take arm semaphore" will result.
(2) This statement is not executable under the compliance control. If this command
is executed under the compliance control, Error " 60FA Not Executable in
compliance control" will result.
Example
ST_ResetCompControl 'Disable compliance control
ST_ResetFrcLimit 'Initialize the force limiting rates