4-axis 6-axis
Vision
device
¤¤¤Available with all series of robots and vision device.
¡¡¡
Available with all series of robots. The command
s
ecifications differ between the 4-axis, 6-axis robot,
and vision device.
¤ V1.2
Available with the 4-axis robots and the 6-axis robots
of Version 1.2 or later.
Classified by functions Commands Functions
4-axis 6-axis
Vision
device
Refer
to:
ST_SetCurLmt
Sets the limit of motor current
to be applied to the specified
axis.
V1.9 V1.9 12-77
ST_ResetCurLmt
Resets the motor current limit
of the specified axis.
V1.9 V1.9 12-79
ST_SetEralw Modifies the allowable
deviation of the specified axis.
V1.9 V1.9 12-80
ST_ResetEralw Resets the allowable deviation
value of the specified axis to
the initial value.
V1.9 V1.9 12-81
ST_OnSrvLock Servo-locks a specified axis. V1.9 12-82
ST_OffSrvLock Releases servo lock for the
specified axis.
V1.9 12-83
ST_SetCompControl Enables the compliance
function.
V1.9 12-84
ST_SetCompFControl
Enables the compliance
control function.
V1.9 12-86
ST_ResetCompControl Disables the compliance
control function.
V1.9 12-87
ST_SetFrcCoord Selects a force limiting
coordinate system.
V1.9 12-88
ST_SetFrcLimit Sets the force limiting rates. V1.9 12-89
ST_ResetFrcLimit Initializes the force limiting
rates.
V1.9 12-90
ST_SetCompRate
Sets the compliance rates
under the compliance control.
V1.9 12-91
ST_ResetCompRate Initializes the compliance
rates.
V1.9 12-92
ST_SetFrcAssist Sets the force assistance
under the compliance control.
V1.9 12-93
ST_ResetFrcAssist
Initializes the force assistance
(special compliance control
function statement).
V1.9 12-94
ST_SetCompJLimit
Sets the current limit under the
compliance control.
V1.9 12-95
ST_ResetCompJLimit Initializes the current limit
under the compliance control.
V1.9 12-96
ST_SetCompVMode Sets the velocity control mode
under the compliance control.
V1.9 12-97
ST_ResetCompVMode
Disables the velocity control
mode under the compliance
control.
V1.9 12-98
ST_SetCompEralw Sets the allowable deviation
values of the position and the
posture of the tool tip under the
compliance control.
V1.9 12-99
ST_ResetCompEralw
Initializes the allowable
deviation values of the position
and the posture of the tool end
under the compliance control.
V1.9 12-100
ST_SetDampRate Sets the damping rates under
the compliance control.
V1.9 12-101
ST_ResetDampRate Initializes the damping rates
under the compliance control.
V1.9 12-102
Commentaires sur ces manuels