12-74
ST_ResetGravity (Statement) [Ver.1.9 or later]
Function
Disables the balance setting between the limited motor torque and gravity torque,
which is made with
ST_SetGravity
.
Format
ST_ResetGravity
Explanation
This command disables the balance setting between the motor torque limited by the
current limit function and gravity torque.
Related Terms
ST_ResetCurLmt, ST_SetEralw
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm-semaphore obtained, Error
"21F7 Cannot take arm semaphore" will result.
(2) If this command is executed when the current limit function is enabled, Error
"665B Cannot disable the gravity compensation" will result. Disable the current
limit function and then try it again.
(3) If you set the gravity offset setting to "0" on the teach pendant, the gravity offset
function becomes disabled. If you do it when the current limit function is
enabled, Error 665b will result, as in step (2).
Example
ST_ResetGravity