Chapter 12 Robot Control Statements
12-89
ST_SetFrcLimit (Statement) [Ver.1.9 or later]
Function
Sets the force limiting rates (exclusively designed for 6-axis robots).
Format
ST_SetFrcLimit <Limiting rate along X>, <Limiting rate along Y>, <Limiting
rate along Z>, <Limiting rate about X>, <Limiting rate about Y>, <Limiting
rate about Z>
Explanation
Sets the force limiting rates along and about X, Y, and Z axes of a coordinate system
specified by ST_SetFrcCoord.
Setting ranges from 0 to 100. Up to two decimal places are valid.
Related Terms
ST_ResetFrcLimit, ST_SetFrcCoord, ST_SetCompControl
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm semaphore obtained, Error
"21F7 Cannot take arm semaphore" will result.
(2) This statement is not executable under the compliance control. If this command
is executed under the compliance control, Error " 60FA Not Executable in
compliance control" will result.
(3) All the set values for along and around the X, Y and Z-axes will be initialized to
100 after the controller is turned on.
Example
ST_SetFrcCoord 1 'Set the compliance coordinate system to
'the tool coordinate
ST_SetFrcLimit 100, 0, 100, 100, 100, 100
'Set the compliance rates
ST_SetCompControl 'Set the compliance rate in Y direction
'of the tool coordinate system to 0% and
'enable the compliance control