LETENV (Statement)
Function
Sets the environment setting values of the system.
Format
LETENV <Table number>, <Element number>, <Setting value>
Explanation
This statement sets the environment setting values of the system designated
with <Table number> and <Element number> to <Setting value>
For the items of the environment setting values, refer to Appendix 3
“Environment Setting Value.
An error may occur when execution starts, if you set an element number or any
set value exceeds the setting range.
Remarks: The easiest way to tell if setting is possible is to open the
manager of WINCAPSII, which controls the table
corresponding to <Table number>, and check the table
screen. If a column of the property does not have a symbol
of “*,” the element in that item can be set. However, you
should log-in with the password level of <programmer>.
Note: If you change the environment setting values, it is recommended
that you restart the controller.
Related Terms
VER$, GETENV
Example
LETENV 6, 22, 5600
'Sets 5600 for the environment setting values of number 6 and 22.