Denso RC5 Spécifications Page 614

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 692
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 613
21-62
Note (1): Designate the processing range with a window.
Note (2): If the specified window is larger than the screen, an error will
result.
Note (3): The following data can be obtained with the processing result
obtaining function.
Note (4): Gauging results (angle) can be obtained only when the
processing range is specified in the sector window (mode=0).
Note (5): The processing screen is the one defined by VISWORKPLN.
Note (6): For this instruction, a µ
µµ
µVision board (option) is required.
Note (7): Increasing the number of steps reduces the detection time but
lowers the resolving power for detection.
Related Terms
WINDMAKE, VISWORKPLN, VISGETNUM, VISSTATUS
¡: Available ×: Not available
Line (2 point specification) Windmake P
¡
Line (Length, angle) Windmake L
¡
Circle Windmake C
×
Ellipse Windmake E
×
Sector Windmake S
¡
Rectangle Windmake R
¡
VISSTATUS (n)
n Item
0 Execution result 0= Normal
-1= Abnormal
1 Number of edges detected
2 Execution time
VISGETNUM (a, b)
b a = 0~511
0 Unknown
1 Coordinate X value
2 Coordinate Y value
3 Angle(Note (4))
4 Unknown
5 Unknown
6 Unknown
7 Unknown
8 Unknown
9 Unknown
Vue de la page 613