VISEDGE (Statement)
Function
Measures the edge in a window.
Format
VISEDGE<Window number>,<Coordinate X>,<Coordinate Y>, <Step>,
<Processing object>, <Level>[,<Mode>[, <Binary lower limit>[,<Binary upper
limit>]]]
Explanation
<Window number> Designates the window number (0 to 511).
<Coordinate X> Designates the X coordinate (0 to 511).
<Coordinate Y> Designates the Y coordinate (0 to 479).
<Step> Designates the scanning direction and the sampling rate (-511 to 511).
Scanned every 2 stepsScanned every step
Edge scanning sampling step
Step number = +1
Edge scanning direction
Edge scanning direction
Step number = positive
Edge scanning direction
Reference
point
Step number = +2
Edge scanning direction
Step number = negative
Edge scanning direction
Edge scan from left to right
In rectangle window (mode 0)
Edge scan from right to left
In rectangle window (mode 0)
Start
position
Refer-
ence
point
Refer-
ence
point
Rerer-
ence
point
<Processing object> Designates the objects to be measured (0 to 2)
0: Turning point from black to white (edge)
1: Turning point from white to black
2: Turning point (both edges 0 and 1)
Kind of edge
When mode = 1 (white to black)
Edge scanning direction
When mode = 0 (black to white)
Edge scanning direction
Edge position
Edge position
The edge scanning direction and the specified value of mode 1 determine the edge detecting position.