Chapter 8. Files
143
Specifying Options in the OPEN "BAR:" Statement
You may also specify several options as listed below for each of the bar code types in the
OPEN "BAR:" statement.
Bar Code Buffer
The bar code buffer stores the inputted bar code data. It will be occupied by one operator
entry job and can contain up to 40 characters in the BHT-3000 and 99 characters in the
BHT-4000/BHT-5000/BHT-6000/BHT-6500/BHT-7000/BHT-7500.
You can check whether the bar code buffer stores bar code data, by using any of the
EOF,
INP, and LOC functions, and the WAIT statement.
Any of the
INPUT# and LINE INPUT# statements, and the INPUT$ function reads bar
code data stored in the buffer into a string variable.
8.3.2 Programming for Bar Code Device
Code Mark
The MARK$ function allows you to check the code type and the length of the inputted bar
code data.
This function returns a total of three bytes: one byte for the code mark (denoting the code
type) and two bytes for the data length.
Multiple Code Reading
You may activate the multiple code reading feature which reads more than one bar code
type while automatically identifying them, by designating the desired bar code types follow-
ing the
CODE in the OPEN "BAR:" statement.
Options
- Check digit (only for ITF, Codabar, Code 39, and STF)
- Read data length
- Start/stop character (only for Codabar and STF)
- Start character flag (only for universal product codes)
- Supplemental code (only for universal product codes. Not supported by the BHT-
3000)